TAMIU Campus Plan Master Plan Update, May 2023

131 Campus Master Plan Update 131 C/ APPENDIX S R Q U T RLC FPA PLANT STC CNS KLM WHT LBV KCB P J N L F D C B A G H K O M I 8" WL 12" WL 16" WL 12" WL 8" WL 8" WL 8" WL 12" WL 8" WL 12" WL 12" WL 12" WL 6" WL 8" WL 6" SAN 8" SAN 8" SAN 6" WL 10" WL 12" WL 8" SAN 6" WL 8" WL 12" WL 8" WL 8" WL 12" SAN 12" SAN 8" WL 8" WL 12" WL 6" WL 4" WL 6" WL 6" WL 4" WL 16" WL 12" WL 8" SAN 16" WL 8" SAN 12" WL 12" WL 8" SAN 8" SAN 8" SAN 12" WL 12" SAN 12" WL 12" SAN 8" WL 12" SAN 12" SAN 6'X4' BOX CULVERT EX. 24" RCP EX. 36" RCP EX. 8" PVC EX. 15" RCP EX. 42" RCP EX. 42" RCP EX. 18" RCP EX. 18" RCP EX. 30" RCP EX. 30" RCP EX. 12" STM PIPE EX. 24" RCP EX. 12" PVC EX. 18" RCP EX. 12" PVC EX. 18" RCP EX. 12" PVC EX. 48" RCP EX. 24" RCP EX. 24" RCP EX. 36" RCP EX. 24" RCP EX. 24" RCP EX. 30" RCP EX. 24" RCP EX. 12" STM PIPE EX. 8" STM PIPE EX. 12" STM PIPE EX. 18" STM PIPE EX. 8" STM PIPE EX. 18" RCP EX. 12" PVC EX. 18" RCP EX. 8" VERTICAL PIPE EX. 12" RCP EX. 12" RCP EX. 18" RCP EX. 4" HDPE (TYP) EX. 4" HDPE (TYP) EX. 18" HDPE EX. 24" RCP EX. 24" RCP EX. 36" RCP EX.24" RCP EX. 4" HDPE (TYP) EX. 2 X 36" STM CULVERTS EX. 24" STM CULVERT EX. 2 X 36" STM CULVERTS EX. 24" STM CULVERT EX. 24" STM CULVERT EX. 36" STM CULVERT EX. 18" STM PIPES Seal and Signature : Issues/Revisions : No. Drawing Title: Date Certification Statement : This document and the information herein is the property of Martinez Moore Engineers, LLC. No part hereof shall be copied, duplicated, distributed, disclosed or used to any extent whatsoever except as expressly authorized by Martinez Moore Engineers, LLC. Any person, firm, or corporation receiving this document, however obtained, shall by virtue hereof, be deemed to have agreed to the forgoing restrictions and that this document will be held in trust and confidence subject only to the private use expressly authorized by Martinez Moore Engineers, LLC. Copyright (c) 2016 by Martinez Moore Engineers, LLC. Project Number : Approved By : Drawn By : Checked By : Filename : TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES. OVERALL SITE EXHIBIT Description Project Status Keyplan : Consultants / Discipline : Client : Project : APR DRW CHK Project Number MARTINEZ MOORE ENGINEERS, LLC 401 SOUTH 1ST STREET, SUITE 600 AUSTIN, TX 78704 PHONE: 512-330-1278 X:\Y03\2021\21008-00 TAMIU Master Plan\2-Design\04-Exhibits\2023-04-06-SITE EXHIBIT\Y03-21008-00-TAMIU MASTER PLAN SITE EXHIBIT.dwg pm PROPOSED 8" WL (PHASE -1 PLAN) DEMO 8" WL (PHASE - 1 PLAN) PROPOSED 8" WL (PHASE - 2 PLAN) PROPOSED 12" WL (PHASE - 2 PLAN) DEMO 12" WL (PHASE -2 PLAN) PROPOSED 12" WL (PHASE - 3 PLAN) DEMO 12" WL PROPOSED 12" WL (PHASE - 3 PLAN) PROPOSED 8" WATER LOOP (PHASE - 3 PLAN) NEAR-TERM PLAN MID-TERM PLAN LONG-TERM PLAN LEGEND: UTILITIES IN THE CLOUDED AREA ARE PROPOSED TO BE REMOVED DEMO 12" SAN PROPOSED 12" SAN EXISITNG SEWER LIFT STATION EXISITNG SEWER LIFT STATION SEWER FORCE MAIN SEWER FORCE MAIN DEMO 8" SAN (PHASE -1 PLAN) PROPOSED 8" SAN (PHASE -1 PLAN) PROPOSED 8" SAN (PHASE-2 PLAN) SEWER FORCE MAIN SEWER FORCE MAIN PROPOSED 8" SAN (EXTENSION FROM PHASE-2 PLAN) (PHASE - 3 PLAN) PROPOSED 8" SAN (PHASE-2 PLAN) ABANDON 12" SAN IN PLACE (PHASE-1 PLAN) PROPOSED 12" SAN (PHASE-1 PLAN) STORM PIPES IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED (PHASE-1 PLAN) STORM PIPES AND INLETS IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED (PHASE-1 PLAN) INLETS IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED STORM PIPES AND INLETS IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED STORM PIPES AND INLETS IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED STORM PIPES AND INLETS IN THIS AREA NEEDS TO BE REMOVED AND RELOCATED PROPOSED WATER LINE - PHASE 1 PROPOSED WATER LINE LOOP - PHASE 3 PROPOSED WATER LINE - PHASE 2 PROPOSED WATER LINE - PHASE 3 PROPOSED SANITARY LINE - PHASE 1 PROPOSED SANITARY LINE - PHASE 2 PROPOSED SANITARY LINE - PHASE 3 TAMIU MASTER PLAN SITE OVERALL SITE TBPE Firm Registration No. F-16839 March, 2023

RkJQdWJsaXNoZXIy Mzk1Mzc4